Overhead drone view of a large standing seam roof, a Manifest Metals job

Architectural metal roofing for commercial buildings in El Paso.

Standing seam and R-panel roofs for offices, schools, churches, retail, shops and metal buildings, with the coping, edge metal and flashing that tie the roof into the walls.

What we bid

The roof, and everything it meets.

On a commercial building the roof, the parapets and the walls meet in a dozen places, and that’s where leaks start. We bid the roof panels and the architectural sheet metal that ties them in.

  • Standing seam: 24 ga, 1-3/4" snap-lock, 18" panels, concealed clips
  • R-panel: 26 ga, 36" coverage, 12 chart colors, for warehouses, shops and metal buildings
  • Panels rolled in El Paso and cut to exact length; for the longest runs we can roll on site
  • Flat and low-slope roofs converted to sloped metal — see flat roof to metal
  • Re-roofs on existing metal buildings: failed fasteners, leaks, flashing and panel replacement
  • Parapet coping, edge metal, counterflashing and penetration flashing, color-matched
  • A different profile or gauge in the spec? Send it, and we’ll tell you straight away what we can bid

Standing seam we’ve installed

RAISED SEAM CONCEALED CLIP
Standing seam, in cross-sectionIllustration. The clip hooks the panel to the deck and hides under the next seam.
MAJOR RIB EXPOSED FASTENER + WASHER
R-panel, in cross-sectionIllustration. Exposed fasteners through the flat; the major ribs carry the strength.

Before bid day

Four things to settle on a metal roof.

  • Pitch

    Our snap-lock standing seam and R-panel both need at least 3:12. Below that, the roof needs a slope built first — see flat roof to metal — or a system tested for low slope.

  • Wind uplift

    The roof should match a tested assembly (UL 580 or ASTM E1592) for the project’s wind pressures. Clip and fastener spacing follow that test, tighter at corners and edges.

  • Heat and movement

    Long panels grow in the afternoon sun and shrink at night. Concealed clips let standing seam move; on R-panel, that daily movement is why fasteners need checking over the years.

  • Cool roofs

    Light, reflective finishes send more of the sun back. The EPA reports reflective cool roofs can cut peak cooling demand 11–27% in air-conditioned buildings.

Specs

What the project manual usually calls it.

Spec sections

Typical MasterFormat sections
07 41 13Metal Roof Panels
07 41 13.16Standing-Seam Metal Roof Panels
07 62 00Sheet Metal Flashing and Trim
07 71 00Roof Specialties (coping, edge metal)

Tests and codes you’ll see

Typical tests and code references
UL 580 / ASTM E1592Wind uplift tests for metal roof assemblies
UL 790 / ASTM E108Fire classification of roof coverings
ASTM E1680 / E1646Air leakage and water penetration of metal roof panels
ANSI/SPRI/FM 4435 ES-1Tested edge metal and coping at low-slope roof edges
IBC §1507.4Code rules for metal roof panels, including minimum slope

Typical references only. We build to your project manual and the manufacturer’s tested assembly; confirm against your Division 07 specs.

Commercial projects

Our commercial work.

We’re documenting our commercial jobs now, and each one goes up only with the GC’s or owner’s OK. Until then, ask us about similar work when you call.

Everything we bid, and how we work with GCs

Bidding a project?

Send us the package and we'll get you a number.

  • Project name and location
  • Drawings, the Division 07 spec sections and any addenda
  • Bid due date
  • Expected construction schedule
  • Your prequalification packet — tell us what paperwork you need
Email plans & specs Or use the bid form

Plan-room links (Procore, BuildingConnected, Dropbox, Google Drive) are fine. Or call (915) 600-7279.

FAQ

Common questions

Don't see yours? Call us — we're happy to talk it through.

Do you re-roof existing metal buildings?

Yes: failed fasteners, leaks, flashing and panel replacement, or a full new roof. We look at it first and tell you in writing what it needs.

Can you convert a flat commercial roof to metal?

Yes. New framing gives the roof a slope, then it’s finished in standing seam or R-panel. Changing a roof’s shape is structural work, so it needs a permit and inspections. How a flat roof becomes a metal roof.

Standing seam or R-panel for a commercial roof?

Standing seam for buildings that want a clean architectural roof with no exposed screws; R-panel for warehouses, shops and metal buildings, where a strong, economical roof makes sense. Our guide compares them side by side.

More systems

The rest of the envelope.

ACM & MCM panels

Aluminum and metal composite facades, canopies, column covers and accent bands, bid to your 07 42 43 spec.

Metal wall panels

R-panel rolled in El Paso, concealed-fastener and flush panels, insulated panels, liners and re-skins.

Soffit & fascia

Canopy, overhang and walkway soffits, fascias and wing panels, in metal or composite panel.

Bidding a project? Send us the plans.